Advertisements
Advertisements
प्रश्न
A potentiometer is used to measure the potential difference between A and B, the null point is obtained at 0.9 m. Now the potential difference between A and C is measured, the null point is obtained at 0.3 m. The ratio `E_2/E_1` is (E1 > E2) ______
विकल्प
3 : 1
3 : 2
2 : 3
1 : 3
MCQ
रिक्त स्थान भरें
उत्तर
A potentiometer is used to measure the potential difference between A and B, the null point is obtained at 0.9 m. Now the potential difference between A and C is measured, the null point is obtained at 0.3 m. The ratio `E_2/E_1` is (E1 > E2) 2 : 3.
Explanation:
`E_{ab}/E_{ac} = L_{ab}/L_{ac} = E_1/(E_1 - E_2) = 0.9/0.3 = 3`
`E_1 = 3E_1 - 3E_2`
`2E_1 = 3E_2`
`E_1/E_2 = 3/2`
∴ `E_2/E_1 = 2/3`
shaalaa.com
Potentiometer
क्या इस प्रश्न या उत्तर में कोई त्रुटि है?