प्रश्न

State the principle of the working of a moving coil galvanometer, giving its labeled diagram ?

उत्तर

Moving coil Galvanometer 

Principle: 

Its working is based on the fact that when a current carrying coil is placed in a magnetic field, it experiences a torque.

Working: 

Suppose the coil PQRS is suspended freely in the magnetic field. 

Let 

= Length PQ or RS of the coil 

= Breadth QR or SP of the coil 

= Number of turns in the coil 

Area of each turn of the coil, × b

Let = Strength of the magnetic field in which coil is suspended

= Current passing through the coil in the direction PQRS 

Let, at any instant, α be the angle which the normal drawn on the plane of the coil makes with the direction of magnetic field.

The rectangular coil carrying current when placed in the magnetic field experiences a torque whose magnitude is given by,

τ = nIBA sin α

shaalaa.com
  क्या इस प्रश्न या उत्तर में कोई त्रुटि है?
2010-2011 (March) All India Set 3

वीडियो ट्यूटोरियलVIEW ALL [2]

संबंधित प्रश्न

A circular coil of 250 turns and diameter 18 cm carries a current of 12A. What is the magnitude of magnetic moment associated with the coil?


A galvanometer has a resistance of 16Ω. It shows full scale deflection, when a current of 20 mA is passed through it. The only shunt resistance available is 0.06  which is not appropriate to convert a galvanometer into an ammeter. How much resistance should be connected in series with the coil of galvanometer, so that the range of ammeter is 8 A?


With the help of a neat and labelled diagram, explain the principle and working of a moving coil galvanometer ?


Figure shows two circuits each having a galvanometer and a battery of 3V.

When the galvanometers in each arrangement do not show any deflection, obtain the ratio R1/R2.


Why are the pole pieces of a horseshoe magnet in a moving coil galvanometer made cylinder in shape? 


The current sensitivity of a galvanometer is defined as ______.


To make the field radial in a moving coil galvanometer ______.

In a moving coil galvanometer the deflection (Φ) on the scale by a pointer attached to the spring is ______.


A galvanometer having a resistance of 20 Ω and 30 Ω division on both sides has figure of merit 0.005 ampere/division. The resistance that should be connected in series such that it can be used as a voltmeter upto 15 volt, is ______.


A voltmeter has a range of 0 - 20 V and a resistance of 500 Q. Explain how can be used to measure voltages from 0 - 200 volt?