प्रश्न
The primary coil having NP turns of an ideal transformer is supplied with an alternating voltage VP. Obtain an expression for the voltage VS induced in its secondary coil having NS turns.
उत्तर
For the simple transformer shown in the figure, the output voltage VS depends almost entirely on the input voltage VP and the ratio of the number of loops in the primary and secondary coils. Faraday's law of induction for the secondary coil gives its induced output voltage VS to be
`V_S = -N_S((Deltaphi)/(Deltat))` .....(i)
Where NS is the number of loops in the secondary coil and `(Deltaphi)/(Deltat)` is the rate of change of magnetic flux.
The cross-section area of the coils is the same on either side, as is the magnetic field strength, and so `(Deltaphi)/(Deltat)` is the same on either side. The input primary voltage VP is also related to changing flux by
`V_P = -N_P(Deltaphi)/(Deltat)` .....(ii)
Lenz's law tells us that the primary coil opposes the change in flux caused by the input voltage VP hence the minus sign is given.
Dividing both the equation, we get
`V_S/V_P = N_S/N_P`
`V_S = V_P(N_S/N_P)`
APPEARS IN
संबंधित प्रश्न
Name the transformer used in the power transmitting station of a power plant.
A circular coil of 100 turns with a cross-sectional area of 1 m2 is kept with its plane perpendicular to the magnetic field of 1 T. The magnetic flux linkage is ______.
A step-down transformer connected to the main supply of 220 V is used to operate 11V,88W lamp. Calculate
- Voltage transformation ratio and
- Current in the primary
A step-up transformer has 300 turns of primary winding and 450 turns of secondary winding. A primary is connected to 150 V and the current flowing through it is 9A. The current and voltage in the secondary are
For an ideal step-down transformer, the quantity which is constant for both the coils is ______.
A transformer is used ______
1 MW power is to be delivered from a power station to a town 10 km away. One uses a pair of Cu wires of radius 0.5 cm for this purpose. Calculate the fraction of ohmic losses to power transmitted if
- power is transmitted at 220 V. Comment on the feasibility of doing this.
- a step-up transformer is used to boost the voltage to 11000 V, power transmitted, then a step-down transfomer is used to bring voltage to 220 V. (ρCu = 1.7 × 10–8 SI unit)
In a transformer, number of turns in the primary coil are 140 and that in the secondary coil are 280. If current in primary coil is 4 A, then that in the secondary coil is ______.
Magnetic flux passing through a coil is initially 4 × 10-4 Wb. It reduces to 10% of its original value in t second. If the emf induced is 0. 72 mV then t in second is ______.
The primary coil of a transformer has 60 turns whereas its secondary coil has 3000 turns.
If a current of 5A flows in the primary coil, how much current will flow in a load in the secondary coil? State the assumption you have made regarding the transformer, in this calculation.