प्रश्न

If numerical aperture of a microscope is increased, then its ______.

विकल्प

  • resolving power decreases

  • limit of resolution decreases

  • resolving power remains constant

  • limit of resolution increases

MCQ
रिक्त स्थान भरें

उत्तर

If numerical aperture of a microscope is increased, then its limit of resolution decreases.

Explanation:

d = `lambda/(2musinalpha)= lambda/(2"N"."A")`

shaalaa.com
Resolving Power
  क्या इस प्रश्न या उत्तर में कोई त्रुटि है?
2013-2014 (October)

APPEARS IN

संबंधित प्रश्न

The resolving power of a telescope depends upon the ______.


Describe Rayleigh's criterion for resolution. Explain it for a telescope and a microscope.


Describe Young’s double-slit experiment with a neat diagram showing points of maximum and minimum intensity. 


An object is clearly seen through an astronomical telescope of length 50 cm. The focal lengths of its objective and eye-piece respectively can be ______.


By increasing the aperture of the objective lens, wavelength of light, focal length of the objective lens and the resolving power of an astronomical telescope respectively.


If the mass of a body is m on the surface of the earth, the mass of the same body on the surface of the moon is ______.


When sunlight is scattered by atmospheric atoms and molecules, the amount of scattered light, of wavelength 440 nm, is 'I'. What amount of light of wavelength 660 nm will be scattered?


When wavelength of light used in optical instruments A and B are 4500 Å and 6000 Å respectively, the ratio of resolving power of A to B will be ______.


According to Abbe, in the formula for resolving power of a microscope, the numerical aperture is represented by ______ 


The aperture of the objective is 24.4 cm. The resolving power of this telescope. If a light of wavelength 2440 Å is used to see the object will be ______.


Wavelength of light used in an optical instrument are λ1 = 4000 Å and λ2 = 5000 Å, then ratio of their respective resolving powers (corresponding to λ1 and λ2) is ______.


In compound microscope, the focal length and aperture of the objective used is respectively ______.


Resolving power of telescope increases when ______.


Which of the following would permit finer detail to be examined using a microscope of a given numerical aperture?


Determine the limit of resolution of a telescope for the light of wavelength 500 nm if the telescope objective has diameter of 5.08 m.


Define the resolving power of a telescope.


State the formula for resolving the power of a telescope.


What are the advantages of using a large objective lens in an astronomical telescope?


Share
Notifications

Englishहिंदीमराठी


      Forgot password?
Use app×